Structured cabling connects the network points in a building to the cabinet and patch panel in an organised pattern, using copper or fibre. Good cabling lasts decades. Bad cabling cannot be fixed by swapping devices; the cable has to be pulled again.
Who it is for
Buildings under construction or renovation, hotels bringing the network to guest rooms, and anyone living with cable chaos. If the cables are unlabelled and nobody knows which goes where, start here.
- New hotel, office or factory construction
- Businesses adding network points during renovation
- Those who need fibre links between floors or buildings
- Places where the cable cabinet is a mess and faults cannot be managed
What we do
Planning, copper and fibre installation, termination, labelling, testing and documentation. Before any wall is drilled, we settle the route and the number of points together.
- Planning: Number and positions of points, cable route, cabinet location.
- Copper cabling: Category cable suited to the building, outlets and patch panel connections.
- Fibre cabling: Fibre runs inside and between buildings, splicing and termination.
- Cable routes: Tray, trunking and conduit work. A clean, accessible route.
- Labelling: Both ends of every point are marked with the same code.
- Testing: Copper points are checked with a certified tester, fibre points with optical measurement.
- Documentation: A point list and markings on the floor plan.
How we work
Cabling follows the construction schedule, and the schedule matters to us as much as the technical side. Cable has to go in before paint and ceilings; pulling it afterwards is expensive and messy.
- Survey and plan: The number of points and the route are set from the drawings or on-site measurement.
- Materials: The list of cable, outlets and panels comes in writing. We advise against going cheap on cable quality.
- Installation: Floor by floor, according to how the business or site is organised.
- Termination and testing: Each point is connected, measured and the result recorded.
- Handover: Documents, measurement reports and a usage note are provided.
What we hand over
Working points and a map of them. When a cable gives trouble, tracing it should take minutes, not hours.
- Labelled copper and fibre points
- Test results per point
- Point markings on the floor plan
- Patch panel and switch connection list
- List of materials used
Brands we work with
Cabling is largely brand-independent, and we choose cable and outlets to suit each project. For active equipment we use Cisco, Ubiquiti, MikroTik and Fortinet as needed.
Frequently asked questions
Copper or fibre?
Within a floor and over short distances, copper is often enough and economical. Between buildings, over long distances or for high-capacity links, fibre is more suitable. Most projects use both.
Is it possible to add cable later?
It is possible, but it can be expensive and untidy. Leaving empty conduit or tray makes adding points later easier. We also recommend writing the points you will need in future into the plan.
Why is labelling so important?
With labels, you find the faulty cable among ten in seconds. Without them you try each one in turn. It looks like a small detail, yet it does more to shorten fault time than anything else.
Is a test report really necessary?
Yes. A cable that has been pulled is not necessarily a cable that works. The measurement report shows its quality and is your reference if problems appear later.